top of page
DiGi M2M
Product
| Xbee ZB Adaptor
Watchport Sensor

- 온도, 습도, 거리, 가속 등 센싱
- USB Interface 용(윈도우 드라이버 제공) 및 Xbee Adaptor 용(무선 지그비 통신) 있음
- 별도의 전원없이 인터페이스 전원 활용
- ConnectPort X 게이트웨이를 통한 원격 모니터링 가능
Watchport/H Humidity/Temperature Sensor
- Collects both relative humidity (RH) and temperature data
- Temperature compensated RH readings
- ASCII command interface
- Maximum reading rate: 20 per second
- Temperature accuracy: +/- 3.6° F (+/- 2° C) at -40° F to 14° F (-40° C to -10° C) and +/- 0.9° F (+/- 0.5° C) at 14° F to 185° F (-10° C to 85° C)
- RH accuracy: +/- 5% at 0-90% non-condensing; +/- 8% over 90%
- RH stability: +/- 1% RH (typical) at 50% RH in 5 years
- Power consumption: 15 mA (normal), 1.0 mA (suspend mode)
- Maximum CAT5 UTP cable length: 500 ft (152.46 m)
Watchport/D Distance/Proximity Sensor
Watchport/T Temperature Sensor
Watchport/W Water Detector
- Photo-electric sensor with hardware controlled sensitivity
- Detection range 1.6 to 4.9 ft (0.5 to 1.5 m)
- Maximum reading rate: 3 per second
- Maximum switching frequency: 100 Hz
- Response delay: ≤5.0 ms (typical)
- Power consumption: 70 mA (max)
- Maximum CAT5 UTP cable length: 500 ft (152.46 m)
- ASCII command interface
- Maximum reading rate: 20 per second
- Temperature accuracy: +/- 3.6° F (+/- 2° C) at -40° F to 14° F (-40° C to -10° C) and +/- 0.9° F (+/- 0.5° C) at 14° F to 185° F (-10° C to 85° C)
- Temperature resolution: 0.1° C
- Power consumption: 15 mA (normal), 1.0 mA (suspend mode)
- Maximum CAT5 UTP cable length: 500 ft (152.46 m)
- 2 gold plated pins detect wetness on a non-conductive surface
- Binary output with "Wet" or "Dry" readings
- Waterproof enclosure
- Maximum reading rate: 5 per second
- Power consumption: 15 mA (normal), 1.0 mA (suspend mode)
- Maximum CAT5 UTP cable length: 1,000 ft (304.8 m)
- •No external power supply required
Watchport/A Accelerometer
- Dual axis accelerometer
- Measures dynamic acceleration such as vibration or static acceleration (gravity)
- Measures tilt to 0.1°
- Acceleration from -2g to 2g
Power Requirements
Environmental
- Operating temperature: -40° F to 185° F (-40° C to 85° C)
- Relative humidity: 0% to 95% (non-condensing)
Usability Requirements
- FCC Part 15, Class B
- CE
- EN55022
- EN55024
- EN60950
- UL 1950
- CSA 2.2 No. 950
- IEC-950
-
Watchport Sensors for Drop-in Networking must be used with XBee Sensor Adapters (sold separately). Please see http://www.digi.com/products/wireless-modems-peripherals/wireless-range-extenders-peripherals/ for XBee Adapter information.
Regulatory Approvals
Dimensions
Watchport/H, Watchport/T, Watchport/W, Watchport/A
- Length: 2.12 in (5.39 cm)
- Width: 1.19 in (3.02 cm)
- Height: 0.69 in (1.75 cm)
- Weight: 3.00 oz (85.05 g)
Watchport/D
- Length: 1.75 in (4.45 cm)
- Width: 0.74 in (1.88 cm)
- Height: 0.85 in (2.16 cm)
- Weight: 3.00 oz (85.05 g)
bottom of page